Main Features and Specifications
Measure concentration of HC, CO, CO2 and
In compliance with accuracy requirement of ISO 3930
or OIML R99 Class 0.
O2 in
automotive exhaust emissions
Chinese or English menu for easy operation
LCD screen
Automatic zero reset
Assembled with advanced NDIR components and gas
sensors
Automatic calculation and display of Air-Fuel Ratio ?
Equipped with RS-232C digital serial communication
interface
Equipped with rotation speed and oil temperature
measure ports
With functions of License Plate Number entry and time
display
800 groups of data storage and review.
Main Technical Specifications
Measuring Range:
HC: 0?9,999 ppm (n-Hexane)
CO: 0?10 %
CO : 0?18 % 2
O : 0?23 % 2
Measurement Accuracy:
HC: ±10 ppm (abs.)
±5 % ( rel. ) (which ever is larger)
CO: ±0.03 % (abs.)
±5 % ( rel. ) (which ever is larger)
CO : ±0.5 % (abs.) 2
±5 % ( rel. ) (which ever is larger)
O : ±0.1 % (abs.) 2
±5 % ( rel. ) (which ever is larger)
HC: 1 ppm
CO: 0.01 %
CO : 0.01 % 2
O : 0.01 % 2
Response Time: Less than 8s(O , less than 12s.) 2
Warm-up Time: 10 min.
(ambient temperature is not lower than 20?)
Power Supply: AC220V ±10% 50Hz ±1Hz or
Weight
Instrument: 11.5Kg
Trolley: 38Kg
Outer Dimension
Instrument: 370mm(W) × 205mm(H) × 470mm(D)
Trolley: 650mm(W) × 990mm(H) × 830mm(D)
?